Reliable Veterinary Test Kits Microplate Reader , Serum H5N1 Test Kit 96T/KIT

    Buy cheap Reliable Veterinary Test Kits Microplate Reader , Serum H5N1 Test Kit 96T/KIT from wholesalers
     
    Buy cheap Reliable Veterinary Test Kits Microplate Reader , Serum H5N1 Test Kit 96T/KIT from wholesalers
    • Buy cheap Reliable Veterinary Test Kits Microplate Reader , Serum H5N1 Test Kit 96T/KIT from wholesalers

    Reliable Veterinary Test Kits Microplate Reader , Serum H5N1 Test Kit 96T/KIT

    Ask Lasest Price
    Brand Name : New Life
    Model Number : 96 wells
    Certification : ISO, CE
    Payment Terms : T/T, Western Union
    Supply Ability : 100000kit/month
    Delivery Time : 20-35days
    • Product Details
    • Company Profile

    Reliable Veterinary Test Kits Microplate Reader , Serum H5N1 Test Kit 96T/KIT

    High accuracy Avian influenza (H5N1) Antibody ELISA Test kit, 96wells/kit,proffesional use


    1. Summary


    This kit use AIV H5N1 solid phase antigen to detect specific antibody against AIV H5N1 antigen, have high sensitivity, specificity, reproducibility, and is easy to operate quickly and can be used dividually in multiple times.


    2. Reagents and contents


    1H5N1 Antigen coated Plate96T×1
    2Enzyme conjugate H5N1-Ab (No.1 solution)6 ml×1
    3Washing solution (No.2 solution)50ml×1
    4Substrate A (No.3 solution)6 ml×1
    5Substrate B (No.4 solution)6 ml×1
    6Sample diluent ( No.5 solution )50 ml×1
    7Stop reaction solution ( No.6 solution )6 ml×1
    8Positive control H5N1-Ab0.8 ml×1
    9Negative control H5N1-Ab0.8 ml×1
    10Adhesive Foil2 pieces
    11Sealed bag1 piece
    12Instruction1 piece

    3. Materials Required But Not Provided


    1 Microplate Reader (Including Wavelength 450nm/630 nm).

    2 37℃ Constant temperature box

    3 Micropipettes, adjustable.


    4. Sample requirement


    1. The samples are serum, storage time should be for 7 days at 2-8 ℃, if for long term, it should be kept at -20℃ or below it. Avoid repeated freezing and thawing.

    2. Avoid to use the samples containing sodium azide, high cholesterol, with bacteria and severe hemolytic


    5. Test procedure


    1. Washing solution preparation

    Dilute washing solution (No.2 solution) with distilled water or deionized water at 1:10, e.g. add 900ml distilled water or deionized water in 100 ml washing solution, and mix thoroughly.

    2. Sample diluent:

    Dilute the serum sample with sample diluent (No.5 solution) at 1:100, e.g. 5 μl serum + 495 μl sample diluent, mix thoroughly.

    3. Adding samples and controls

    For each test, set 2 wells for Negative control, 2 wells for positive control. Add negative control, positive control respectively, 100μl/well. Set one blank control well, add nothing. For sample well, add diluted serum sample, 100μl/well. Incubation at 37 ℃ in dark for 30 minutes. Discard liquid of the wells and fill all wells with diluted washing solution, incubate for 1 minute and discard. Repeat washing procedure 3 times as above. At the end of the washing step, carefully remove remaining fluid by tapping the strips on the tissue paper prior to the next step.

    4. Adding Enzyme conjugate

    Apart from the blank control well, add 100ul Enzyme conjugate (No.1 solution) into all wells and incubate at 37 ℃ in dark for 30 minutes. Discard liquid of the wells and wash 3 times as described in step 3.

    5. Adding substrates

    Mix Substrate A (No.3 solution) and Substrate B (No.4 solution) in equal volumes, add into each well, 100μl/well, incubate at 37 ℃ dark for 10 minutes.

    6. Add one drop of Stop reaction solution ( No.6 solution ) into all wells. Before reading results with ELISA microtiter plate reader, set the reagent blank well A1 to zero . Measure the OD Value of all wells at 450 nm (reference wavelength: 630 nm).


    6. Reference


    Validation judge

    OD Value of negative control well ≤0.15 (Invalid if > 0.15);

    OD Value of positive control well ≥0.30 (Invalid if < 0.30).


    7. Interpretation of results


    OD value of sample ≥ OD Value of Positive control mean X 1.1: H5N1 Antibody Positive;

    OD value of sample <OD Value of Positive control mean X 0.9: H5N1 Antibody Negative;

    OD Value of Positive control mean X 0.9 < OD value of sample< OD Value of Positive control mean X 1.1: Skeptical, this sample need review;

    OD Value of sample review ≤OD Value of Positive control mean X 1.1: H5N1 Antibody Negative


    8. Limitation


    This kit is only suitable for testing chicken serum.


    9. Notes


    1) Microwell should be sealed and moisture-proof. MicroWell plate removed from the refrigerated environment should be balanced moisture to dry at room temperature, then can be opened. Put back unused MicroWell plate into dry foil bag and sealed at 4 ℃.

    2) Before dropping reagent, shake dropping bottle gently to even, discard the first drop; Keep the dropping bottle upright when adding reagents.

    3) Cover the gap tightly after using every time. Do not mix using the cap. Do not use reagents from different lot.

    4) Treat the used kits and reagents as pollution material. The stop solution is corrosive, be careful to use.


    ORIENT NEW LIFE MEDICAL CO., LTD.
    Contact:Jerry Meng
    Email:Jerry @ newlifebiotest .com
    Tel.+86 18657312116
    SKYPEenetjerry