Sign In | Join Free | My himfr.com
Home > Cardiac Blood Tests >

One Step H-FABP Cardiac Blood Tests Multiple Cassette Gold Colloidal For Health

    Buy cheap One Step H-FABP Cardiac Blood Tests Multiple Cassette Gold Colloidal For Health from wholesalers
     
    Buy cheap One Step H-FABP Cardiac Blood Tests Multiple Cassette Gold Colloidal For Health from wholesalers
    • Buy cheap One Step H-FABP Cardiac Blood Tests Multiple Cassette Gold Colloidal For Health from wholesalers

    One Step H-FABP Cardiac Blood Tests Multiple Cassette Gold Colloidal For Health

    Ask Lasest Price
    Brand Name : New Life
    Model Number : cassette
    Certification : ISO13485,CE
    Payment Terms : T/T, Western Union
    Supply Ability : 2000000pcs/month
    Delivery Time : 20-30days
    • Product Details
    • Company Profile

    One Step H-FABP Cardiac Blood Tests Multiple Cassette Gold Colloidal For Health

    One Step multiple cassette H-FABP/Cardiac Troponin I Combo cardiac blood Tests , gold colloidal method, quickly and easily


    Intended Use:


    The H-FABP/Cardiac Troponin I Combo Rapid Test Cassette (Whole Blood/Serum/Plasma) is a rapid chromatographic immunoassay for the qualitative detection of human H-FABP and cardiac Troponin I (cTnI) in whole blood, serum or plasma as an aid in the diagnosis of myocardial infarction (MI).


    Summary:


    FABP is a newly introduced plasma marker of acute myocardial infarction (AMI). The plasma kinetics of FABP (15 kD) closely resemble those of myoglobin in that elevated plasma concentrations are found within 2 hours after AMI and return to normal generally within 18 to 24 hours. But the concentration of FABP in the skeletal muscle is 20 times lower than in cardiac tissue (for myoglobin the same content for cardiac and skeletal tissue), that makes FABP to be more cardiac specific than myoglobin. This makes FABP a useful biochemical marker for the early assessment or exclusion of AMI. FABP also appears to be a useful plasma marker for the estimation of myocardial infarct size. FABP is suitable for use as a standard in immunoassay for early detection of acute myocardial infarction, immunogen for antisera production, mass FABP standard, FABP biochemical and immunochemical studies, tracer for iodination. Cardiac Troponin I (cTnI) is a protein found in cardiac muscle with a molecular weight of 22.5 kDa.1 Troponin I is part of a three subunit complex comprising of Troponin T and Troponin C. Along with tropomyosin, this structural complex forms the main component that regulates the calcium sensitive ATPase activity of actomyosin in striated skeletal and cardiac muscle. After cardiac injury occurs, Troponin I is released into the blood 4-6 hours after the onset of pain. The release pattern of cTnI is similar to CK-MB, but while CK-MB levels return to normal after 72 hours, Troponin I remains elevated for 6-10 days, thus providing for a longer window of detection for cardiac injury. The high specificity of cTnI measurements for the identification of myocardial damage has been demonstrated in conditions such as the perioperative period, after marathon runs, and blunt chest trauma. cTnI release has also been documented in cardiac conditions other than acute myocardial infarction (AMI) such as unstable angina, congestive heart failure, and ischemic damage due to coronary artery bypass surgery. Because of its high specificity and sensitivity in the myocardial tissue, Troponin I has recently become the most preferred biomarker for myocardial infarction. The H-FABP/Cardiac Troponin I Combo Rapid Test Cassette (Whole Blood/Serum/Plasma) is a simple test that utilizes a combination of antibody coated particles and capture reagents to qualitatively detect H-FABP and cardiac Troponin I (cTnI) in whole blood, serum or plasma. The minimum detection level is 8 ng/mL H-FABP and 0.5 ng/mL Troponin I.


    Test Principle:


    The H-FABP/Cardiac Troponin I Combo Rapid Test Cassette (Whole Blood/Serum/Plasma) is a qualitative, membrane based immunoassay for the detection of H-FABP and cardiac Troponin I (cTnI) in whole blood, serum or plasma. The membrane is pre-coated with specific capture antibodies in each of the test line regions of the test. During testing, the whole blood, serum or plasma specimen reacts with the particle coated with specific antibodies. The mixture migrates upward on the membrane chromatographically by capillary action to react with specific capture reagents on the membrane and generate a colored line. The presence of this colored line in the specific test line region indicates a positive result, while its absence indicates a negative result. To serve as a procedural control, a colored line will always appear in the control line region indicating that proper volume of specimen has been added and membrane wicking has occurred.


    TEST PROCEDURE


    1. Bring the pouched test device to room temperature(15-30℃) prior to testing. Do not open the pouch until ready

    to begin testing.

    2. Remove the device from the sealed pouch and lay it on a flat and dry surface.

    3. Using the provided pipette, add one drop of fresh specimen to the sample well.

    4. Hold the buffer bottle vertically and add 1 drop to the sample well. /If using a pipette, change a new one to avoid cross-contamination. Draw and transfer 2-3 drops of buffer to the sample well.

    5. Read the result between 15-20minutes. Do not read results after 20 minutes.


    Limitation

    1. The H-FABP/Cardiac Troponin I Combo Rapid Test Cassette (Whole Blood/Serum/ Plasma) is for in vitro diagnostic use only. This test should be used for the detection of H-FABP, and cardiac Troponin I (cTnI) in whole blood, serum or plasma specimens only. Neither the quantitative value nor the rate of increase in H-FABP and cardiac Troponin I can be determined by this qualitative test.
    2. The H-FABP/Cardiac Troponin I Combo Rapid Test Cassette (Whole Blood/Serum/ Plasma) will only indicate the qualitative level of H-FABP and Troponin I in the specimen and should not be used as the sole criteria for the diagnosis of myocardial infarction.
    3. The H-FABP/Cardiac Troponin I Combo Rapid Test Cassette (Whole Blood/Serum/Plasma) cannot detect less than 8ng/mL H-FABP and 0.5ng/mL cardiac Troponin I (cTnI) in specimens. A negative result at any time does not preclude the possibility of myocardial infarction.
    4. As with all diagnostic tests, all results must be interpreted together with other clinical information available to the physician.
    5. Some specimens containing unusually high titers of heterophile antibodies or rheumatoid factor (RF) may affect expected results. Even if the test results are positive, further clinical evaluation should be considered with other clinical information available to the physician.
    6. There is a slight possibility that some whole blood specimens with very high viscosity or which have been stored for more than 2 days may not run properly on the test cassette. Repeat the test with a serum or plasma specimen from the same patient using a new test cassette.

    PERFORMANCE CHARACTERISTICS


    Sensitivity and Specificity


    The Cardiac Combo Rapid Test Card has been evaluated with a leading commercial H-FABP/Troponin I EIA test using clinical specimens. The results show that relative to leading EIA test.


    H-FABP Test vs. EIA
    MethodEIATotal
    H-FABPResultsPositiveNegativeResults
    Positive54155
    Test
    Negative0422422
    Total Results54423477
    Relative Sensitivity: 100% (93.4%-100.0%) *
    Relative Specificity: 99.8% (98.7%-99.9%)*
    Accuracy: 99.8%(98.8% to 99.9%)*(* 95% Confidence Interval)

    Troponin I Test vs. EIA


    MethodEIATotal
    Negativ
    ResultsPositiveResults
    e
    cTnI Test
    Positive2258233
    Negative3505508
    Total Results228513741

    Relative Sensitivity: 98.7% (96.2%- 99.7%)*


    Relative Specificity: 98.4% (97.0%-99.3%)*


    Accuracy: 98.5% (97.4%-99.3%)* (* 95% Confidence Interval)


    ORIENT NEW LIFE MEDICAL CO., LTD.
    Contact:Jerry Meng
    Email:Jerry @ newlifebiotest .com
    Tel.+86 18657312116
    SKYPEenetjerry
    Quality One Step H-FABP Cardiac Blood Tests Multiple Cassette Gold Colloidal For Health for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Orient New Life Medical Co.,Ltd.
    *Subject:
    *Message: