Sign In | Join Free | My himfr.com
Home > Surgical Ligating Clip >

Non - Absorbable Polymer ligating Clip For Vessel Ligation Use , 3 -5 Years Warranty

    Buy cheap Non - Absorbable Polymer ligating Clip For Vessel Ligation Use , 3 -5 Years Warranty from wholesalers
     
    Buy cheap Non - Absorbable Polymer ligating Clip For Vessel Ligation Use , 3 -5 Years Warranty from wholesalers
    • Buy cheap Non - Absorbable Polymer ligating Clip For Vessel Ligation Use , 3 -5 Years Warranty from wholesalers
    • Buy cheap Non - Absorbable Polymer ligating Clip For Vessel Ligation Use , 3 -5 Years Warranty from wholesalers
    • Buy cheap Non - Absorbable Polymer ligating Clip For Vessel Ligation Use , 3 -5 Years Warranty from wholesalers
    • Buy cheap Non - Absorbable Polymer ligating Clip For Vessel Ligation Use , 3 -5 Years Warranty from wholesalers

    Non - Absorbable Polymer ligating Clip For Vessel Ligation Use , 3 -5 Years Warranty

    Ask Lasest Price
    Brand Name : New Life
    Model Number : S,M,L
    Certification : ISO, CE,FDA
    Payment Terms : T/T, Western Union
    Supply Ability : 100000 catridge/month
    Delivery Time : 10 days
    • Product Details
    • Company Profile

    Non - Absorbable Polymer ligating Clip For Vessel Ligation Use , 3 -5 Years Warranty


    Non- absorbable Polymer ligation clip for vessel ligation use

    Polymer Ligating Clips are implantable medical devices made of an advanced polymer to ensure a high level of biocompatibility along with the structural and dimensional stability over time, necessary for long-lasting patient safety. They are designed to combine the speed of the metal clip with outstanding security comparable to 2.0 suture. This combination leads to extreme time savings. The inner surface of the legs of Polymer ligating clip has staggered opposed teeth arrangement inclined towards the gripped tissue. In a number of procedures, Polymer Ligating Clips successfully replace endostaplers or the harmonic scalpel, combining highest security level with cost savings. Equally important is the low interference with CT scanning, radiolucency in X-rays and the great safety in MRIs resulting in the lack of artifacts. Every clips is fitted with the hinge and the latch tested in thousands of procedures.


    Model and Size


    SIZEPRODUCT SPECIFICATIONCOLORPCS. PER CARTRIDGE
    Sligating range from 1 mm to 7 mmBLUE6 Clips/ Cartridge 14 Cartridges/ Box
    Mligating range from 3 mm to 10 mmGREEN6 Clips/ Cartridge 14 Cartridges/ Box
    Lligating range from 5 mm to 13 mmPURPLE6 Clips/ Cartridge 14 Cartridges/ Box
    XLligating range from 7 mm to 16 mmGOLDEN6 Clips/ Cartridge 14 Cartridges/ Box


    Key Feature


    - 4 sizes to ligate tissue structures from 2mm to 16mm,

    - ligate up to a 10mm tissue through a 5mm trocar or up to16mm through a 10mm trocar,

    - easy loading system,

    - removers available to unlock the clip,

    - clips delivered in color-coded cartridges for easy identification,

    - 4 or 6 clips per cartridge to ensure economical and comfortable use of the product,

    - 20cm, 27cm and 27cm 70° angled clip appliers with properly sized jaws,

    - color-coded applier rings for easy identification.


    Advantage


    - non-absorbable polymer = unlimited hold-on time

    - penetrating lock = fast and effective closure, security on the tissue, tactile feedback on closure

    - self-leading lock = no scissoring of the clip

    - precision bosses = security in the applier – no dropouts, no slip-back, tactile feedback on

    loading

    - bowed shape = ability to encompass more tissue

    - living hinge = flexibility during opening and closing, no over-closing

    - integrated teeth = no slippage on the tissue


    Loading Clips and Inserting the applier down the cannula

    1. To load the applier, grasp the applier and carefully insert the jaws of the applier into the cartridge slot, making sure the jaws are perpendicular to the base of the cartridge. Gently press the applier over the clip until there is an audible double click.Do not force the applier into the cartridge or onto the clip. The applier should enter and withdraw from the cartridge easily.

    2. Remove the applier from the cartridge ensuring the clip is held securely in the applier jaws. The clips bosses should seat in the notches of the applier jaws ( picture 1). It may be necessary to hold the cartridge to allow the clip to be removed.

    3. Compress the applier handles and insert the applier jaws and shaft down the cannula. Maintain compression on the applier handles until the jaws clear the cannula. Clip positioning and closure

    1). During application, Orient the single tooth of the clips as shown(picture1). This allows the user to visually confirm encapsulation of the structure being ligated.

    2) Position the clip around the tissue to be ligated in a manner that provides clear visualization of the locking

    mechanism.(picture2). NOTE: Avoid excess tissue in the locking mechanism of the clip. Apply sufficient force

    to the applier handles so the jaws close and the clip locks shut(picture3).

    • Releasing pressure on the applier handles allows the applier to return to a fully open position.
    • Releasing pressure on the applier handles allows the applier to return to a fully open position.
    PROCEDURE WHY Polymer ligation clip
    GENERAL SURGERY
    RIGHT, LEFT AND MIDDLE COLECTOMY

    Saves time due to tissue penetration, tactile feedback on loading, tactile feedback on closure, no clip dropouts, no scissoring, the ability to encompass more tissue, the highest stability

    and security on tissue. Does not interfere with CT and MRI imaging.

    ANTERIOR COLO-RECTAL RESECTION

    Saves time due to tissue penetration, tactile feedback on loading, tactile feedback on closure,

    no clip dropouts, no scissoring, the ability to encompass more tissue, the highest stability and security on tissue. Does not interfere with CT and MRI imaging.

    APPENDECTOMY

    Saves cost due to endostaplers replacement. The tactile feedback ensures correct closure in

    poor visibility location. No clip dropouts.

    CHOLECYSTECTOMY

    One clip for the ligation of the cystic duct even when enlarged. Excellent stability and security

    on tissue.


    GASTRECTOMY

    Saves time due to tissue penetration, the tactile feedback on loading, the tactile feedback on closure, no clip dropouts, no scissoring, ability to encompass more tissue, highest stability and security on tissue resulting in fast ligation of the short gastric vessels. Does not interfere

    with CT and MRI imaging.


    NISSEN FUNDOPLICATION

    Saves time due to tissue penetration, the tactile feedback on loading, the tactile feedback on closure, no clip dropouts, no scissoring, the ability to encompass more tissue, the highest stability and security on tissue resulting in fast ligation of the short gastric vessels. Does not

    interfere with CT and MRI imaging.

    SPLENECTOMYExcellent stability and security on tissue
    UROLOGY
    PROSTATECTOMY

    Easy to apply in a surgical field with difficult or limited exposure due to its excellent stability

    in the applier. No clip dropouts. Does not interfere with CT and MRI imaging.

    ADRENALECTOMY

    Security due to latch mechanism, the tactile feedback on closure and excellent stability on

    tissue. No clip dropouts. Does not interfere with CT and MRI imaging.

    NEPHRECTOMYSecurity due to latch mechanism, the tactile feedback on closure and excellent stability on tissue. No clip dropouts. Does not interfere with CT and MRI imaging.
    GYNECOLOGY

    HYSTERECTOMY

    Both in total abdominal and laparoscopically assisted vaginal hysterectomies offers extreme security due to latch mechanism, the tactile feedback on closure and excellent stability on

    tissue.

    THORACIC SURGERY

    PULMONECTOMY, LOBECTOMY,

    SEGMENTECTOMY

    Saves time due to the tactile feedback on loading, the tactile feedback on closure, no clip dropouts, no scissoring. Extreme stability and security on vessel. Does not interfere with CT

    and MRI imaging.

    VASCULAR SURGERY

    VARICOSE VEIN SURGERY

    Saves time due to tissue penetration, the tactile feedback on loading, the tactile feedback on

    closure, no clip dropouts, no scissoring, the ability to encompass more tissue, highest stability and security on vessels.


    Packaging Details

    6 pcs per cartridge, 14 cartridges per box.

    50/100 boxes per carton


    Storage Conditions

    Temperature: < 54 °C

    Relative Humidity: 0% to 80%


    Quality Non - Absorbable Polymer ligating Clip For Vessel Ligation Use , 3 -5 Years Warranty for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Orient New Life Medical Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)